need to remove certain alarms for only certain type of interfaces, and worked many days and finally worked with help from TAC.
1. Modified
group rule for a customizable interface group with a valid group rule (Example:
Customizable Interface Group 1) from Admin > System > Group Management > Fault.
2.
Modified the priority of that Interface
Threshold Group to higher priority from Monitor > Fault Settings > Setup > Priority Settings so that the interfaces satisfying the
rule will fall under higher priority group.
3. Apply
changes after modifying the priority to apply all changes to in charge
server from Monitor > Fault Settings > Setup > Apply Changes.
4. Then
apply threshold values from Monitor > Fault Settings > Setup > Threshold Settings.
5.
Then
apply changes to apply all threshold value changes to in charge server
from Monitor > Fault Settings > Setup > Apply Changes